W1308 DC/AC 12V/220V Red/Blue LED Thermostat Temperature Controller Sensor12V Thermostat Red/Blue LED
Description:100% brand new and high qualityTemperature control range: -50 ~ 120 ° CMeasurement Accuracy: 0.1 ° CControl accuracy: 0.1 ° CHysteresis accuracy: 0.1 ° CRefresh rate: 0.5 SInput Power: DC 12VMeasuring inputs: NTC (10K 0.5% ) Waterproof sensor 0.5MOutput: 1 Channel relay output, capacity = 10AEnvironmental requirements: -10 ~ 60 ℠Humidity 20% -85% Size: 10*4.8*2.5cmFridge freezer ,display cabinets temperature control, plastic greenhouse, Incubator,Medical equipment, pet house, planting and breeding industry, electrical control cabinet cooling, ventilation containers, reptiles insulation, EPS incubator, sauna, PC cases, civil and industrial equipmentEasy and convenient to useWork light: Red/BluePackage Content:1 x Temperature Control Switch 220V Thermostat Blue/Red LEDDescription:
Temperature control range: -55~ 110 ° CControl accuracy: 0.1 ° C
Input Power: AC 220V
Measuring inputs: NTC (10K 0.5% ) Waterproof sensor 0.5M
Output capacity: MAX 10A
Size: 100 (L) * 48 (W) * 28 (D) mm
Display :Blue/Red
Display window Size :37 x 18mm
Fixed pitch : M3/86mmPackage Included:
1PCS*220V Electronics Thermostat Temperature Controller 12V Thermostat Red Dual LED
Instructions
1. Connect the power supply and load according to the instructions. Be careful not to overpressure and overload!
2. Setting mode, long press SET for 5 seconds will display P0 Short press SET to set H (red light) to heating mode C (green light) to cooling mode
3. Set the stop temperature, press the SET screen once. Press the up and down keys to directly set the desired temperature.
4. ENT is the confirmation button. Press and hold this button to realize the function of power on/off.
Technical parameters:
The Parameter Function Description:
P0 cooling and heating mode
High temperature start for cooling mode, please set to C
Low temperature start for heating mode, please set to H
P1 hysteresis setting
In heating mode (H): measured value ≤ set value - start output heating to set value stop when returning
In cooling mode (C), when the measured value ≥ set value hysteresis, the output cooling is started to the set value stop.
P2 limits the maximum setting (non-temperature setting)
P3 defines the lowest set value (non-temperature control setting)
P4 temperature correction
When the measured temperature deviates from the standard temperature, this function can be used to correct the corrected temperature = temperature before correction correction value
P5 delay start time (unit: minute)
When controlling the cooling of the compressor equipment, the delay time can be set as needed. When the controller outputs, the equipment will not start immediately, and it needs to start after the set delay time.
P6 high temperature alarm
When the measured value is greater than this value, the screen is displayed -- and the sound alarm is dropped. Simultaneously disconnect the output
P7 data lock function
Turn on the data lock to keep the current settings from being changed. At this time, the setting temperature and function are invalid. If you need to modify it, you need to turn off the data frequency function.
P8 factory reset
Long press SET to switch to P8, press SET to set to on, press ENT to restore factory settings
You can also press and hold the - button to disable the POST and restore the factory settings. Instructions for using
Please connect the power supply according to the parameters and wiring diagram, and connect the cooling or heating equipment to the output.
Enter the internal setting as needed to select the heating (into PO selection H) or cooling (into PO selection C) mode to set the temperature method, press the SET screen once, press the upper and lower to set the desired temperature, press ENT to confirm the OUT indicator of the return panel. Light: Blinking indicates cooling or heating start delay, always on indicates output
Digital tube: Display LLL for sensor open circuit: display HHH is out of measurement range, thermostat will force power off, display --- for high temperature alarm. Schematic Diagram: Notice:
1. Input terminal is connected to the power supply. V is the positive GND is the negative pole. Do not exceed the range according to the type of power supply.
2, the output type is relay output, the load needs to be connected in series at the output, the maximum capacity is 10A
3. After connecting the line, you must first set the cooling or heating. When finished, press the SET screen when the temperature is normally displayed. Press the up and down to set the required stop temperature.
4. Before starting the machine, press and hold the power up and down to release the factory to restore the factory settings. Package Included:1PCS*W1308 12V 10A Digital Dual Red LED Display Thermostat Alarm Controller NTC 10K 1% 3950 Cable
Features:Stainless steel sheath and waterproof
Measurement range: -20 to 105 °C
Length of wire: 1 meter
Size of probe: 5 x 25 mm
Output 2 wires
Type: NTC 10k±1% 3950
measure environmental temperatures using arduino ADC and this 10k NTC LINK
Resistance to temperature conversion table LINK
B-constant : 3380K -/ 1%
Typical Dissipation Constant 5mW/ °C
Probe insulation: >100MOhm
Peak Voltage sustain time: 2 seconds, AC1800V 1mA 2 seconds
Stress sustain: 9.8N (1kgF) for 1 minute no deformation
Package Included:1PCS * NTC Thermistor Temperature Sensor Waterproof Probe Cable 1M 10K 1% 3950